MOQ: 100Metal Bent Curved Noise Barrier Arc Acoustic Panel
Curved-top barrier: 1.5–2.5 dB(A) more than a straight wall of the same height, for 8–12% more panel area instead of 33%. Made for capped heights.

Metal Upright Noise Barrier Vertical Sound Wall Panel

The economical baseline: galvanised absorptive panel between H posts, 80 or 100 mm, 10–20 dB(A). Lowest cost per m² of any barrier type, repairable bay by bay.
Not every site needs a composite cassette. Where the requirement is moderate, the run is long, and the budget is fixed, a plain vertical metal panel between H-section posts is still the cheapest way to buy a decibel — and pretending otherwise is how projects end up with a barrier that is 40% over budget and 1 dB better.
This is the baseline product: a galvanised absorptive panel, a standard post, a straight top.
| Parameter | Value |
|---|---|
| Panel height | 2.0–4.0 m |
| Panel width | 0.5 m |
| Panel thickness | 80 mm or 100 mm |
| Face | 0.8 mm perforated galvanised steel |
| Core | 50 mm mineral wool, 80 kg/m³ |
| Rear face | 0.6 mm solid galvanised steel |
| NRC / STC | 0.85 / 32 |
| Insertion loss | 10–20 dB(A), site dependent |
| Zinc coating | ≥120 g/m² |
| Post | H-section steel |
| Standards | GB/T 19889, ISO 717 |
Urban roads, expressways, railway lines, metro at grade, industrial plants, and residential community protection where the barrier line is close to the source.
Two cases justify stepping up to a heavier or curved product: the wall has to exceed about 4 m, or the site is a dual carriageway where a reflective face would push noise to the other side. In both cases the extra spend buys geometry or absorption, not a better panel — and the difference in delivered dB is usually larger than the difference in price.
Lead time 10–20 days. FOB Tianjin, CIF, or DDP.
Every site listed here shares three constraints: continuous traffic or machine load, wind pressure set by local code, and an acoustic target the authority will measure after installation. Panels are selected by insertion loss, NRC and wind load rating — panel size alone tells you nothing about whether the wall will pass.
The economical baseline: galvanised absorptive panel between H posts, 80 or 100 mm, 10–20 dB(A). Lowest cost per m² of any barrier type, repairable bay by bay.
| Panel Height | 2.0-4.0m |
|---|---|
| Panel Width | 0.5m |
| Panel Thickness | 80-100mm |
| Outer Skin | 0.8mm perforated galvanized steel |
| Core | 50mm mineral wool 80 kg/m³ |
| Inner Skin | 0.6mm solid galvanized steel |
| NRC | 0.85 |
| STC | 32 |
| Insertion Loss | 10-20 dB(A) |
| Zinc Coating | ≥120g/m² |
| Post Type | H-section steel |
| Standard | GB/T 19889, ISO 717 |
FOB Tianjin, per m2
Loading figures are typical for standard export packing; the final loading plan is confirmed with the quotation.
Trial orders of 50 m² are accepted for noise barrier panels.
Test reports available on request from our sales manager.
FOB Tianjin. Indicative price for reference only; final quotation valid 30 days from issue.
Factory-direct price · FOB / CIF · Reply within 24 hours
MOQ: 100Curved-top barrier: 1.5–2.5 dB(A) more than a straight wall of the same height, for 8–12% more panel area instead of 33%. Made for capped heights.
MOQ: 80Transparent barrier: 15 mm PC at STC 30, 12–20 kg/m², or 10+10 laminated glass at STC 33. Slotted fixings and UV-coextruded sheet, because thin clamped panels fail.
MOQ: 200Full acoustic enclosure: 4–6 m walls, 8–20 m span, louvered roof with a PC daylight band. 20–30 dB(A) where a wall cannot get past the sixth floor.
MOQ: 100★ Featured3.0 m absorptive highway barrier: 100 mm cassette, NRC 0.85, STC 32, 10–15 dB(A) at the receiver. The base seal decides whether you get it.