Angu Wire Mesh
Angu Wire Mesh

Noise Barrier Panels & Sound Walls

The panel decides how much noise you actually stop — not the post. Every system below is a 100 mm galvanised steel cassette with a mineral-wool core, built to the insertion loss your site has to meet. Choose the height and the face: perforated steel where the noise is broadband, transparent acrylic where the view has to stay open, a fully enclosed tunnel where the source has to disappear.

  • Panel heights 2.0–4.0 m, 0.5 m modules, 100 mm cassette thickness
  • STC 32–34, NRC 0.85, insertion loss 10–15 dB(A) to GB/T 19889 / ISO 717
  • 0.8 mm perforated + 0.6 mm solid galvanised skins, 80 kg/m³ rock wool, A1 non-combustible
  • Transparent PC / acrylic option for bridges and viaducts

Noise Barriers

View all products →
Metal Upright Noise Barrier Vertical Sound Wall PanelMOQ: 100

Metal Upright Noise Barrier Vertical Sound Wall Panel

The economical baseline: galvanised absorptive panel between H posts, 80 or 100 mm, 10–20 dB(A). Lowest cost per m² of any barrier type, repairable bay by bay.

$20Details →
Metal Bent Curved Noise Barrier Arc Acoustic PanelMOQ: 100

Metal Bent Curved Noise Barrier Arc Acoustic Panel

Curved-top barrier: 1.5–2.5 dB(A) more than a straight wall of the same height, for 8–12% more panel area instead of 33%. Made for capped heights.

$26Details →
Transparent Acrylic & Glass Noise Barrier PC PanelMOQ: 80

Transparent Acrylic & Glass Noise Barrier PC Panel

Transparent barrier: 15 mm PC at STC 30, 12–20 kg/m², or 10+10 laminated glass at STC 33. Slotted fixings and UV-coextruded sheet, because thin clamped panels fail.

$28Details →
Fully Enclosed Noise Barrier Tunnel Sound EnclosureMOQ: 200

Fully Enclosed Noise Barrier Tunnel Sound Enclosure

Full acoustic enclosure: 4–6 m walls, 8–20 m span, louvered roof with a PC daylight band. 20–30 dB(A) where a wall cannot get past the sixth floor.

$30Details →
Highway Noise Barrier 3.0m Sound-Absorbing Steel PanelMOQ: 100★ Featured

Highway Noise Barrier 3.0m Sound-Absorbing Steel Panel

3.0 m absorptive highway barrier: 100 mm cassette, NRC 0.85, STC 32, 10–15 dB(A) at the receiver. The base seal decides whether you get it.

$21Details →
Equipment Noise Barrier 2.5m Acoustic Steel PanelMOQ: 50

Equipment Noise Barrier 2.5m Acoustic Steel Panel

2.5 m modular acoustic wall for machinery: removable bays, washable perforated face, A1 core. Shielding the dominant face beats a taller wall in the wrong place.

$22Details →
Industrial Factory Noise Barrier Wall 4.0m Acoustic PanelMOQ: 100

Industrial Factory Noise Barrier Wall 4.0m Acoustic Panel

4.0 m plant perimeter wall: 120 mm build, 80 kg/m³ core, STC 34, HEB 120 posts at 1.0 kPa. Sized for a boundary limit that is measured at night.

$23Details →
Rail Transit Noise Barrier Metro & Light Rail Acoustic PanelMOQ: 100★ Featured

Rail Transit Noise Barrier Metro & Light Rail Acoustic Panel

Rail barrier with 100 kg/m³ core, rubber-isolated panels and EN 16272 data. Built for low-frequency train noise and pressure pulses, not road traffic.

$25Details →
Bridge & Viaduct Noise Barrier Transparent Acoustic PanelMOQ: 100★ Featured

Bridge & Viaduct Noise Barrier Transparent Acoustic Panel

Bridge barrier from 12–20 kg/m²: 15 mm PC at STC 30 or 10+10 laminated glass at STC 33, 1.5–2.0 kPa wind load, 2 million-cycle fatigue rating.

$24Details →

How we build and deliver them

Factory photos, delivered project cases, the full acoustic spec sheet and the quote form are on the solutions page.

Open the noise barrier overview

Frequently Asked Questions

Which model suits a highway project?
The 3.0 m highway panel is the default for road and rail corridors: steel cassette, absorptive face, H-section posts at 2.0 m centres. On a viaduct use the bridge model — it is lighter and takes transparent panels where the road authority wants the view kept.
What is the minimum order?
50 m² for equipment enclosures, 80 m² for transparent panels, 100 m² for the standard road and factory panels, 200 m² for a fully enclosed tunnel. Smaller trial runs can be combined with a container already going to your port.
Can you meet a specified insertion loss?
Yes. Send the target figure and the site conditions; we adjust panel thickness, core density and the absorptive face, then quote against the tested values. The standard build measures 10–15 dB(A).
How are the panels packed?
Panels are stacked and steel-banded on pallets, posts and fittings bundled separately. The loading plan is issued with the packing list before shipment, so you can plan the crane and the unloading crew.