MOQ: 100Metal Upright Noise Barrier Vertical Sound Wall Panel
The economical baseline: galvanised absorptive panel between H posts, 80 or 100 mm, 10–20 dB(A). Lowest cost per m² of any barrier type, repairable bay by bay.

Highway, industrial, rail & bridge noise barriers — plus gabion boxes, fencing and protection nets. ISO 9001 certified, factory-direct.
Angu Wire Mesh is a professional noise barrier manufacturer in Anping, China. Our product range spans 9 lines: highway, industrial, rail and bridge noise barriers, gabion boxes, chain link fence, welded wire mesh, and protection nets. ISO 9001:2015 certified, factory-direct.
Showing 30 products
MOQ: 100The economical baseline: galvanised absorptive panel between H posts, 80 or 100 mm, 10–20 dB(A). Lowest cost per m² of any barrier type, repairable bay by bay.
MOQ: 100Curved-top barrier: 1.5–2.5 dB(A) more than a straight wall of the same height, for 8–12% more panel area instead of 33%. Made for capped heights.
MOQ: 80Transparent barrier: 15 mm PC at STC 30, 12–20 kg/m², or 10+10 laminated glass at STC 33. Slotted fixings and UV-coextruded sheet, because thin clamped panels fail.
MOQ: 200Full acoustic enclosure: 4–6 m walls, 8–20 m span, louvered roof with a PC daylight band. 20–30 dB(A) where a wall cannot get past the sixth floor.
MOQ: 100★ Featured3.0 m absorptive highway barrier: 100 mm cassette, NRC 0.85, STC 32, 10–15 dB(A) at the receiver. The base seal decides whether you get it.
MOQ: 502.5 m modular acoustic wall for machinery: removable bays, washable perforated face, A1 core. Shielding the dominant face beats a taller wall in the wrong place.
MOQ: 1004.0 m plant perimeter wall: 120 mm build, 80 kg/m³ core, STC 34, HEB 120 posts at 1.0 kPa. Sized for a boundary limit that is measured at night.
MOQ: 100★ FeaturedRail barrier with 100 kg/m³ core, rubber-isolated panels and EN 16272 data. Built for low-frequency train noise and pressure pulses, not road traffic.
MOQ: 100★ FeaturedBridge barrier from 12–20 kg/m²: 15 mm PC at STC 30 or 10+10 laminated glass at STC 33, 1.5–2.0 kPa wind load, 2 million-cycle fatigue rating.
MOQ: 200GL-100 passive barrier: ring net and 100 kJ energy absorption to ETAG 027. Sized by rockfall trajectory energy, which is why the height is not a catalogue number.
MOQ: 500DNS-50 active system: 3.0 mm high-tensile mesh, 50 kJ capacity, ETAG 027 and GB/T 31444. Anchors and plate layout come with the design, not after it.
MOQ: 1002.5 mm body wire, 3.0 mm selvedge, ≥250 g/m² zinc — the heavy coating that survives river abrasion. EN 10223-3, ASTM A974.
MOQ: 506 × 2 × 0.3 m mattress, 2.0 mm body and 2.4 mm selvedge, ≥220 g/m² zinc. Built for canal lining where a box would stand too proud.
MOQ: 100358 profile welded panel: 76.2 x 12.7 mm aperture, 4.0 mm wire welded at every intersection. No toehold for a climbing boot, no cut with hand tools.
MOQ: 100HESCO-type bastion cell, 4.0 mm wire welded to NATO STANAG 2280 and MIL-STD-810. Fills with local soil; ships flat at a fraction of the deployed volume.
MOQ: 1008/6/8 construction: two 8 mm horizontal wires clamping a 6 mm vertical, 50 x 200 mm aperture. Stiffer than single-wire mesh, cheaper than 358.
MOQ: 1003.0 m anti-climb panel on Y-posts, two strands of barbed wire angled outward. For airport, duty-free, prison and border perimeters where going over is the risk.
MOQ: 50Rental-fleet panel: 1-5/8 in OD frame, 2 in x 4 in welded mesh, stackable steel feet. Couplers and pins match existing North American stock.
MOQ: 50AS 4687 panel: 2100 mm high, 2400 mm wide, 32 mm frame, 60 x 150 mm mesh. Concrete block or plastic foot, clips to link panel to panel.
MOQ: 202.5 m maximum-security blast barrier on 5.0 mm wire, tested to ASTM F2781 and DOS SD-STD-02. Supplied with the anchor design, not just the panel.
MOQ: 501.1 × 2.0 m crowd barrier at ~25 kg, with a straight or angled top rail and interlocking ends. Designed for push load, not for looks.
MOQ: 2003.0 mm wire at 50 mm mesh for ball-impact duty, not garden duty. ≥120 g/m² zinc, ASTM A392 and EN 10223-2, panel heights to 6 m.
MOQ: 5050 mm chain link, 2.5 mm wire, ≥120 g/m² heavy zinc option. Heights 1.0–4.0 m with matching posts, rails and tension bands, not panels alone.
MOQ: 100BTO-22 concertina coil, blade and core both ≥120 g/m² zinc. The blade coating is the part that decides whether it still deters after two monsoons.
MOQ: 50Euro fence: 2.0 mm core wire with 0.5 mm PVC, welded into a rigid 50 mm panel. The coating is bonded, not sleeved, so it does not peel at cut ends.
MOQ: 10012 × 14 gauge double-strand barbed wire, 4-point barbs at 75–100 mm, ≥80 g/m² zinc. The standard agricultural spec, priced by the coil.
MOQ: 5025 mm double-twist hex mesh, 0.8 mm standard wire, ≥80 g/m². The twist holds its shape when cut, which is why it works for gabion and poultry alike.
MOQ: 50Graduated hinge-joint field fence, 900–1200 MPa high-tensile wire, Class 1 or Class 3 zinc. The graduated spacing is what keeps calves in.
MOQ: 10SS304 or SS316 crimped screen, 2.0 mm wire, 10 mm aperture, lock-crimped so the weave cannot shift. For screening and filtration, not fencing.
MOQ: 5050 × 50 mm welded mesh, 2.0 mm wire, post-weld hot-dipped ≥80 g/m² — welded first, galvanised after, so every intersection is coated.
Gabion boxes and reno mattresses retain earth and water — what decides their service life is stone size against mesh aperture and the zinc coating on the wire, not the price per square metre. Chain link, welded mesh and field fence control access, where the coating class decides how many years the fence lasts before it rusts through. Noise barriers, rockfall barriers and blast walls are engineered systems: the panel is one component, and the post, foundation and connection detail carry the load. Ask for the system drawing, not only the panel price.
Wire diameter, zinc coating mass (g/m²) and the edge wire decide whether two quotes for the same nominal mesh are actually the same product. A 2.7 mm wire with 60 g/m² coating and a 3.4 mm wire with 240 g/m² are both sold as "80×100 gabion mesh", and they will not last the same ten years on a coastal riverbank. Fix all three in writing before comparing prices, and ask which standard the coating is tested to — EN 10244-2 is the one that matters in export contracts.
Noise barrier panels start at 50 m² per specification — 100 m² for mixed highway and rail profiles, 200 m² for fully enclosed tunnels. Gabion, fencing and wire mesh lines start between 50 and 500 m², depending on whether the mesh is woven to order or cut from stock. Catalogue specifications ship within 20 days of deposit; custom sizes, colours and coating classes are confirmed per order. Send the specification table or the drawing and we quote against it line by line.
Common questions about our wire mesh products, specifications, and ordering.