MOQ: 100Metal Upright Noise Barrier Vertical Sound Wall Panel
The economical baseline: galvanised absorptive panel between H posts, 80 or 100 mm, 10–20 dB(A). Lowest cost per m² of any barrier type, repairable bay by bay.

Industrial Factory Noise Barrier Wall 4.0m Acoustic Panel

4.0 m plant perimeter wall: 120 mm build, 80 kg/m³ core, STC 34, HEB 120 posts at 1.0 kPa. Sized for a boundary limit that is measured at night.
A plant boundary is a different problem from a roadside. The wall has to run for hundreds of metres, stand in an industrial atmosphere, survive vehicle impact at the base, and still meet a boundary limit that is often measured at night when the plant is at full load and the neighbourhood is quiet.
At 4.0 m this wall is sized for that duty, with a heavier panel than the highway standard: 120 mm thick, 80 mm of 100 kg/m³ mineral wool, STC 34.
| Parameter | Value |
|---|---|
| Panel height | 4.0 m (up to 6.0 m on request) |
| Panel width | 0.5 m |
| Panel thickness | 120 mm |
| Face | 0.8 mm perforated galvanised steel |
| Core | 80 mm mineral wool, 100 kg/m³ |
| Rear face | 0.6 mm solid galvanised steel |
| Edge frame | 2.0 mm galvanised channel |
| NRC / STC | 0.85 / 34 |
| Insertion loss | 12–18 dB(A), site dependent |
| Fire rating | A1 |
| Post | HEB 120 |
| Post spacing | 2.0 m |
| Design wind load | 1.0 kPa |
| Standards | GB/T 19889, ISO 717 |
Power plants, steel mills, cement and aggregate plants, mining and chemical sites, logistics warehouses with dock activity, and construction equipment yards.
Most boundary complaints are about a single source, not the whole plant: a fan, a compressor house, a loading bay. A perimeter wall reduces the general level, but if one source is 10 dB above everything else it will still be the number the inspector records. Ask for a source survey before sizing the wall, and place the wall between that source and the receptor rather than uniformly around the site.
Lead time 15–25 days, 25–35 days for coastal coating or non-standard heights. FOB Tianjin, CIF, or DDP.
Every site listed here shares three constraints: continuous traffic or machine load, wind pressure set by local code, and an acoustic target the authority will measure after installation. Panels are selected by insertion loss, NRC and wind load rating — panel size alone tells you nothing about whether the wall will pass.
4.0 m plant perimeter wall: 120 mm build, 80 kg/m³ core, STC 34, HEB 120 posts at 1.0 kPa. Sized for a boundary limit that is measured at night.
| Panel Height | 4.0m |
|---|---|
| Panel Width | 0.5m |
| Panel Thickness | 120mm |
| Outer Skin | 0.8mm perforated galvanized steel |
| Core | 80mm mineral wool, 100 kg/m³ |
| Inner Skin | 0.6mm solid galvanized steel |
| Frame | 2.0mm galvanized steel edge channel |
| NRC | 0.85 |
| STC | 34 |
| Insertion Loss | 12-18 dB(A) |
| Fire Rating | A1 |
| Post Type | H-section HEB 120 |
| Post Spacing | 2.0m |
| Wind Load | 1.0 kPa |
| Standard | GB/T 19889, ISO 717 |
FOB Tianjin, per m2
Loading figures are typical for standard export packing; the final loading plan is confirmed with the quotation.
Trial orders of 50 m² are accepted for noise barrier panels.
Test reports available on request from our sales manager.
FOB Tianjin. Indicative price for reference only; final quotation valid 30 days from issue.
Factory-direct price · FOB / CIF · Reply within 24 hours
MOQ: 100The economical baseline: galvanised absorptive panel between H posts, 80 or 100 mm, 10–20 dB(A). Lowest cost per m² of any barrier type, repairable bay by bay.
MOQ: 100Curved-top barrier: 1.5–2.5 dB(A) more than a straight wall of the same height, for 8–12% more panel area instead of 33%. Made for capped heights.
MOQ: 80Transparent barrier: 15 mm PC at STC 30, 12–20 kg/m², or 10+10 laminated glass at STC 33. Slotted fixings and UV-coextruded sheet, because thin clamped panels fail.
MOQ: 200Full acoustic enclosure: 4–6 m walls, 8–20 m span, louvered roof with a PC daylight band. 20–30 dB(A) where a wall cannot get past the sixth floor.